The exhaust gas and compressed air first enter the mixing chamber, and after being fully mixed, enter the heated catalytic chamber, where the hydrocarbons are converted into carbon dioxide and water under the action of the catalyst.
Protection function: When the compressed air is interrupted, it will cause the catalyst to react quickly, and the temperature will rise quickly; At this time, the over temperature shutdown system automatically starts, switches the exhaust gas to the air outlet, and turns off the heater power supply. Double protection, more secure!
• Can be used in dangerous areas, explosion-proof level meets Exd IIC T3;
• No need to use gas recovery system, low cost;
• The product has no back pressure and can be used for special emission instruments, such as chromatographic analyzers;
• Lower maintenance;
• Compact structure for easy installation;
• With automatic switching dual protection function.
Explosion-proof Class | Class 1, Division1, Groups B, C, D |
Processing capacity | Maximum 100L/H |
Hydrocarbon removal efficiency | 100% organic matter |
Compressed air pressure | not less than 2bar |
Exhaust pressure | 10-1bar |
Inlet compressed air dew point | greater than the ambient temperature 5℃ |
Shell surface temperature | maximum 70℃ |
Preheating time | 30 min |
Power supply | 220 VAC/50 Hz, 约400W |
Weight | 约20kg |
Size | Height 70 cm* Width 50 cm* depth 15 cm |
Compressed air interface | 1/4 "NPT internal thread |
Exhaust port | 1/4 "NPT internal thread |
Power interface | 3/4 "NPT Gran |